You are here :Products > On-line UPS > Galleon On-Line UPS
Products
Product lines
Line Interactive UPS
Vesta 450/650/850 UPS
Arista 400/600/800 UPS
Arista LCD 400/600/800 UPS
Arista 1K/1.5K/2K UPS
Orion 500/625/750 UPS
On-Line UPS
Galleon Online UPS
Inverter & AVR
Libra Inverter
Megatron Inverter
Altai Inverter
Scudo AVR
Galleon On-Line UPS

Galleon Online UPS

Brochure
Main Features
True double-conversion
Wide input voltage range (110-300 VAC)
Input power factor correction 0.98
Output power factor 0.8
50/60 Hz frequency converter mode
Programmable power management outlet
Emergency power off (EPO) function
Optional eco-mode operation for energy saving (ECO)
Generator compatible
Charger capacity expansion to 9A for long-run model
SNMP+USB+RS-232 multiple communications
3-step intelligent charging design for 6K/10K
Maintenance bypass available for 6K/10K
N+X parallel redundancy available for 6K/10K models
 
Overview
With true double-conversion design, Galleon series provides powerful and overall protection to your sensitive devices. It can accept wider input voltage for harsh environment. It's perfect protection for your precisous servers and workstaiosn.
Specifications
MODEL
Galleon 1K(L)
Galleon 1.5K
Galleon 2K(L)
Galleon 3K(L)
Galleon 6K(L)
Galleon 10K(L)
Capacity
1000 VA / 800 W
1500 VA / 1200 W
2000 VA / 1600 W
3000 VA / 2400 W
6000 VA / 4800 W
10000 VA / 8000 W
INPUT
Voltage Range Low Line Transfer
160 VAC / 140 VAC / 120 VAC / 110 VAC ¡Ó 5 % or
80 VAC / 70 VAC / 60 VAC / 50 VAC ¡Ó 5 %
(based on load percentage 100% - 80% / 80% - 70% / 70% - 60% / 60% -0)
176 VAC @ 100% load
110 VAC @ 50% load
Low Line Comeback
175 VAC ¡Ó 5 % or 85 VAC ¡Ó 5 %
186 VAC @ 100% load
120 VAC @ 50% load
High Line Transfer
300 VAC ¡Ó 5 % or 150 VAC ¡Ó 5 %
300 VAC
High Line Comeback
290 VAC ¡Ó 5 VAC or 143 VAC ¡Ó 3 VAC
290 VAC
Frequency Range
47.5 Hz ~ 52.5 Hz or 57 Hz ~ 63 Hz
46 ~ 54 Hz @ 50 Hz/56 ~ 64 Hz @ 60 Hz
Phase
Single phase with ground
Power Factor
¡Ù 0.95
¡Ù 0.99 @ 100% load
OUTPUT
AC Voltage Regulation (Batt. Mode)
¡Ó3%
¡Ó 1%
Frequency Range (Synchronized Range)
48 ~ 52 Hz or 57 ~ 63 Hz
46 ~ 54 Hz @ 50 Hz/56 ~ 64 Hz @ 60 Hz
Frequency Range (Batt. Mode)
50 Hz ¡Ó 0.25 Hz or 60 Hz ¡Ó 0.3 Hz
50/60 Hz ¡Ó 0.1 Hz
Current Crest Ratio
3 : 1
Harmonic Distortion
¡Ø 3 % THD (Linear Load)
¡Ø 6 % THD(Non-linear Load)
¡Ø 4 % THD (Linear Load)
¡Ø 7 % THD (Linear Load)
¡Ø 2 % THD (Linear Load)
¡Ø 6 % THD (Linear Load)
Transfer Time AC to DC
Zero
Inverter to Bypass
4 ms (Typical)
Zero
Waveform (Batt. Mode)
Pure Sine Wave
EFFICIENCY
To AC Mode
~ 85 %
~ 88 %
90 %
To Battery Mode
83 %
88 %
BATTERY
Standard Model Battery Type
12 V / 7 AH
12 V / 9 AH
12 V / 7 AH
12 V / 9 AH
12 V / 7 AH
12 V/ 9 AH
Numbers
3
3
6
6
20
20
Typical Recharge Time
4 hours recover to 90% capacity
7 hours recover to 90% capacity
8 hours recover to 90% capacity
Charging Current (max.)
1.0 A
1.0 A
Charging Voltage
41.0 VDC ¡Ó 1%
82.1 VDC ¡Ó 1%
273.0 VDC
Long-run Model Battery Type
Depending on the capacity of external batteries
Numbers
Charging Current (max.)
8.0 A
4.0 A
Charging Voltage
41.0 VDC ¡Ó 1%
82.1 VDC ¡Ó 1%
273.0 VDC
INDICATORS
LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge tiumer, and Fault conditions
LED Panel
UPS status, Load level, Battery level, and Fault indicators
ALARM
Battery Mode
Sounding every 4 seconds
Low Battery
Sounding every second
Overload
Sounding twice every second
Fault
Continuously sounding
PHYSICAL
Dimension, D X W X H (mm)
338.5 X 145 X 220
387 X 190 X 318
526 X 250 X 576.5
Net Weight (kgs)
14
7
14
29.5
16
29.5
16
90
35
93
38
OPERATING ENVIRONMENT
Humidity
20-90 % RH @ 0- 40¢XC (non-condensing)
Noise Level
Less than 50dB @ 1 Meter
Less than 55dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB
Supports Windows 98 SE/ME/NT 4.x/2000/2003/XP/Vista/2008
Optional SNMP
Power management from SNMP manager and web browser
* L means long-run model
    *Specifications are subject to change without further notice.

 

  E-mail
2008 © Voltronic Power Technology Corporation.  All right reserved.