Winner Pro 1KVA-10KVA Online UPS
Winner Pro 1KVA-10KVA Online UPS

Winner Pro is specifically designed for operation in poor power areas. They provides high power density with long backup time in compact size. It’s ideal for ATMs, banking and other business critical applications. Users also can adjust charging current from 1A to 6A according to different applications.

Main Features
  • True double-conversion
  • Microprocessor control optimizes reliability
  • Output power factor 0.8
  • Wide input voltage (110 V – 300 V)
  • Converter mode available
  • ECO mode for energy saving (Only available for 1-3KVA)
  • Generator compatible
  • Smart SNMP works well with either USB or RS-232 together
  • Comprehensive display allows easy monitoring and access of UPS status
  • Input power factor correction
  • Adjustable battery number only available for 6K and up models
  • Optional isolation transformer available
  • Emergency power off (EPO) function is only available for 6K/10K models
  • (Please check with sales directly)


ModelWinner Pro 1K (L)Winner Pro 2K (L)Winner Pro 3K (L)
PHASESingle phase with ground
CAPACITY1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W
INPUT
Nominal Voltage100/110/115/120/127VAC or 200/208/220/230/240VAC
Input Voltage Range55-150 VAC or 110-300 VAC at 50% load
85-140 VAC or 160-280 VAC at 100% load
Frequency Range40 Hz ~ 70 Hz
Power Factor≧0.99 @ Nominall Voltage (100% load)
OUTPUT
Output Voltage100/110/115/120/127VAC or 200/208/220/230/240VAC
Voltage Requlation± 1 %
Frequency Range (Synchronized Range)47~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Batt. Mode)50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
Current Crest Ratio3:1
Harmonic Distortion≦ 3 % THD (Linear Load)
≦ 6 % THD (Non-linear Load)
Transfer
Time
AC to DCZero
Inverter to Bypass4 ms (Typical)
Waveform (Batt. Mode)Pure Sinewave
EFFICIENCY
To AC Mode88% 88% 90%
To Battery Mode83% 87% 88%
BATTERY
Standard
Model
Battery Type12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah
Numbers2 4 6
Typical Recharge Time4 hours recover to 90% capacity
Charging Current (Max.)1.0 A
Charging Voltage27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1%
Long-run
Model
Battery Type Depending on the capacity of external batteries
Numbers 2 3 4 6 8 6 8
Charging Current (Max.)1A/2A/4A/6A (Adjustable)
Charging Voltage27.4VDC
± 1%
41.0VDC ± 1% 54.7 VDC
±1%
82.1 VDC
±1%
109.4VDC
±1%
82.1 VDC
±1%
109.4VDC
±1%
INDICATORS
LCD DisplayLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ALARM
Battery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinously sounding
PHYSICAL
Standard
Model
Dimension, DxWxH (mm)282 x 145 x 220 397 x 145 x 220 421 x 190 x 318
Net Weight (kgs)9.8 17 27.6
Long-run
Model
Dimension, DxWxH (mm)282 x 145 x 220 397 x 145 x 220
Net Weight (kgs)4.1 6.8 7.4
ENVIRONMENT
Humidity20-90 % RH @ 0- 40°C (Non-condensing)
Noise LevelLess than 50dBA @ 1 Meter
MANAGEMENT
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC
Optional SNMPPower management from SNMP manager and web browser
Model Winner Pro 5K (L) Winner Pro 6K (L) Winner Pro 10K (L)
PHASESingle phase with ground
CAPACITY5000VA / 4000W6000VA / 4800W10000 VA / 8000 W
INPUT
Nominal Voltage208/220/230/240VAC
Input Voltage Range110-300 VAC (Based on load at 50%)
176-300 VAC (Based on load at 100%)
Frequency Range46~54 Hz or 56~64 Hz
Power Factor≧0.99 @ Nominall Voltage (100% load)
OUTPUT
Output Voltage208/220/230/240VAC
Voltage Requlation± 1 %
Frequency Range (Synchronized Range)46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode)50 Hz or 60Hz ± 0.1 Hz
Current Crest Ratio3:1
Harmonic Distortion≦ 3 % THD (Linear Load)
≦ 5 % THD (Non-linear Load)
Transfer TimeAC to DCZero
Inverter to BypassZero
Waveform (Batt. Mode)Pure Sinewave
EFFICIENCY
To AC Mode 89% 92% 93%
To Battery Mode 88% 90% 91%
BATTERY
Standard ModelBattery Type12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah
Numbers 8 16 16 20
Typical Recharge Time4 hours recover to 90% capacity 9 hours recover to 90% capacity
Charging Current (Max.)1.0 A 1 A / 2 A
Charging Voltage115.2 VDC ±1%218.4 VDC ±1%218.4 VDC ±1% 273VDC ±1%
Long-run Model Battery Type Depending on the capacity of external batteries
Numbers 8 16 16 20
Charging Current (Max.)1A/2A/4A/6A (Adjustable) 1A/2A/4Adjustable)
Charging Voltage115.2 VDC ±1% 218.4 VDC ±1% 218.4 VDC ±1% 273VDC ±1%
INDICATORS
LCD DisplayLoad level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ALARM
Battery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinously sounding
PHYSICAL
Standard
Model
Dimension, DxWxH (mm)442 x 190 x 688369 x 190 x 688442 x 190 x 688
Net Weight (kgs) 43 61 66 75
Long-run ModelDimension, DxWxH (mm)442 x 190 x 318369 x 190 x 318 442 x 190 x 318
Net Weight (kgs) 15 12 16 18
ENVIRONMENT
Humidity0-95% RH @ 0-40°C
(non-condensing)
0-95% RH @ 0-50°C
(non-condensing)
0-95% RH @ 0-40°C
(non-condensing)
Noise LevelLess than 58dBA@ 1 Meter Less than 55dBA@ 1 Meter Less than 58dBA@ 1 Meter
MANAGEMENT
Smart RS-232/USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC
Optional SNMPPower management from SNMP manager and web browser
*1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC
6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC
**Long-run model is only available in 200/208/220/230/240VAC systems (200VAC system only available for 1-3KVA).
Product specifications are subject to change without further notice.
Download

Winner Pro 1KVA-10KVA_Brochure_2016 - Brochure
WinnerPro-1-3K-LED-Tower - User's Manual
WinnerPro-6-10KVA - User's Manual
Winner Pro-6-10KVA_Tower-Rack_Manual_2016 - User's Manual
WinnerPro-1-3K-Tower+Rack - User's Manual