Galleon 3-phase in/1-phase out 10KVA/15KVA/20KVA Online UPS
Galleon 3-phase in/1-phase out 10KVA/15KVA/20KVA Online UPS

With true double-conversion design, Galleon series provides powerful and overall protection to your sensitive devices. It can accept wider input voltage for harsh environment. It's perfect protection for your precisous servers and workstaiosn.

Galleon 3-phase in/1-phase out 10KVA/15KVA/20KVA Online UPS
Galleon 3-phase in/1-phase out 10KVA/15KVA/20KVA Online UPS
Galleon 3-phase in/1-phase out 10KVA/15KVA/20KVA Online UPS
Galleon 3-phase in/1-phase out 10KVA/15KVA/20KVA Online UPS
Main Features
  • True double-conversion
  • DSP technology guarantees high performance
  • Output power factor 0.8
  • Wide input voltage range (110-300 VAC)
  • Built-in phase auto adapt function simplifies wire installation
  • 50Hz/60Hz frequency converter mode
  • Eco mode operation for energy saving (ECO)
  • Programmable power management outlets
  • Emergency power off function (EPO)
  • Generator compatible
  • Charger capacity expansion to 8A for long-run models
  • SNMP+USB+RS-232 multiple communications
  • 3-stage extendable charging design for optimized battery performance
  • Adjustable battery numbers
  • Maintenance bypass available
  • Optional N+X parallel redundancy
  • Optional isolation transformer available


ModelGalleon 3/1-10K (L)Galleon 3/1-10K ISO (L)Galleon 3/1-15K (L)Galleon 3/1-20K (L) Galleon 3/1-20K ISO( L)
PHASE3-phase in / 1-phase out
CAPACITY10000 VA/8000 W10000 VA/8000 W15000 VA/12000 W20000 VA/16000 W20000 VA/16000 W
INPUT
Input Voltage Range305-478 VAC (3-phase) at 100% load
190-520 VAC (3-phase) at 50% load
Frequency Range46~54Hz or 56~64Hz
Power Factor≧ 0.99 @ 100% Load
OUTPUT
Output Voltage208/220/230/240VAC104/110/115/120VAC or 208/220/230/240VAC208/220/230/240VAC104/110/115/120VAC or 208/220/230/240VAC
AC Voltage Regulation (Batt. Mode)± 1%
Frequency Range (Synchronized Range)46~54Hz or 56~64Hz
Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio3:1
Harmonic Distortion≦ 2 % THD (Linear Load) ≦ 5 % THD (Non-linear Load)≦ 2 % THD (Linear Load) ≦ 6 % THD (Non-linear Load)≦ 2 % THD (Linear Load) ≦ 5 % THD (Non-linear Load≦ 2 % THD (Linear Load) ≦ 5 % THD (Non-linear Load)≦ 2 % THD (Linear Load) ≦ 7 % THD (Non-linear Load
Transfer TimeAC Mode to Batt. ModeZero
Inverter to BypassZero
Waveform (Batt. Mode)Pure Sinewave
EFFICIENCY
AC Mode89%85%89%89%87%
Battery Mode86%83%88%87%83%
BATTERY
Standard ModelBattery Type12 V / 9 Ah
Numbers20 pcs (18-20 pcs adjustable)*20 pcs x 2 strings (18-20 pcs adjustable)*N/A
Typical Recharge Time9 hours recover to 90% capacityN/A
Charging Current (Max.)1A1A2A2AN/A
Charging Voltage273 VDC ± 1%
Long-run ModelBattery TypeDepending on applications
Numbers
Charging Current (Max.)4A4A8A
Charging Voltage273 VDC ± 1%
INDICATORS
LCD DisplayUPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery ModeSounding every 4 seconds
Low BatterySounding every second
OverloadSounding twice every second
FaultContinously sounding
PHYSICAL
Standard ModelDimension, DxWxH (mm)592 x 250 x 576592 x 250 x 826815 x 250 x 826N/A
Net Weight (kgs)83144164164
Long-run ModelDimension, DxWxH (mm)592 x 250 x 576592 x 250 x 826592 x 250 x 576592 x 250 x 576815 x 250 x 826
Net Weight (kgs)28914040144
ENVIRONMENT
Humidity0-95 % RH @ 0- 40°C (Non-condensing)
Noise LevelLess than 58dB @ 1 MeterLess than 60dB @ 1 Meter
MANAGEMENT
Smart RS-232/USBSupports Windows 2000/2003/XP/Vista/2008, Windows 7, Linux, Unix, and MAC
Optional SNMPPower management from SNMP manager and web browser
*When using internal batteries from 18-19, the unit will de-rate according to the below formula: P = PRating x N/20 .
** Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC.
***If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
Download

Galleon 3P/1P 10KVA/15KVA/30KVA - Brochure
Galleon 3P/1P 10KVA/15KVA/20KVA - User's Manual
Galleon 3P/1P 10KVA/15KVA/20KVA+ISO - User's Manual